PFX2511
Lineup
Data sheet
Note:To view the PDF file, please use Adobe Reader Ver.6 or later.
Operation Manuals
To download operation manuals (PDF), please use "Operation Manual Database".
Products Index > Electronic Loads and Battery Testers > PFX2511
PRODUCTS
PFX2511
Charge/Discharge System Controller : 2 Models
Outline
PFX2511 is a high performance Charge/Discharge system controller that enables measuring charge/discharge voltage and current of secondary batteries with high precision by combining our DC power supply and electronic load.
In these years, voltage (number of stack) and capacity (Ah value) of secondary batteries have become varied, and it is required to support the diversity for characteristic evaluation and the test equipment. However, general purpose test equipment cannot support measuring and evaluating large capacity batteries. Therefore, there was no choice but make the special system.
The PFX2511 equips with our technology of Charge/Discharge control and high accurate measurement required for battery characteristic evaluation. Combination of our DC power supply, electric load and the PFX2511 realizes configuring high precision battery test system with ease.
Note: To configure the charge and discharge test system, it the selected Kikusui's power supply, electronic load, a PC, and communication control unit (PFX2121) are required.
Features
- The system for charge and discharge testing can be configured with the selected Kikusui's electronic load and the DC power supply.
- The applicable maximum voltage : 60.0000 V
- The applicable maximum current : 50.0000 A
- The operating mode : Charge mode (CC-CV, CC ) / Discharge mode (CC, CP, CC Pulse, CP pulse)
- Equipped with an electric input/output terminal, load switch (route switch circuit)
- Supports temperature measurement
- Equipped with the vibration sensor (auto stop function) .
- Included the application software "BPChecker2000 Basic edition (Up to 2CH)"
The "BPChecker 2000 Basic Edition", a standard accessory, can manage the entire operation from the setting of the test conditions, the execution of the test, and analyzing the test result files. This software can controll the thermostatic chambers (manufactured by ESPEC) and also applies to the synchronized test with the thermostatic chambers.System configuration (example)
The recommended operating environment :
CPU: Pentium IV 1GHz or higher / Memory 512 MB or more / Windows 2000 Professional (SP4 + Update Roll up1), Windows XP (SP2 or later with Intel x86) or Windows Vista (Intel x86,x64) / USB interface (GPIB interface is required for controlling the thermostatic chamber)
The figure shows the overlapped graph of charging curve (discharge, charge + discharge ), it is also capable of calculating the average, standard deviation, max or min value, and the data analysis.
Q & A
The example system configuration consists of the charge/discharge system controller "PFX2511", the DC power supply "PWR800L", and the electronic load "PLZ1004W". The dimention of the system may differ depends on the configuration of the selected models. The PFX2121 (communication control unit) is also required for the control by the PC. (USB connection)
The PFX2511 can be configured with the below specified combination. Each of the system configuration is assigned for the specific model ID, The future combination of model ID shall be assigned by upgrading the application software, please visit our website for the latest information.
Model ID Power supply for charge E-load for discharge 5101 (M range) PWR800L PLZ1004W 5102 (H range) PWR800L PLZ1004W 5103 PWR1600L PLZ1004W x 2 5104 PWR800L PLZ334W 5106 PWR1600L PLZ1004W 5107 PAS10-70 PLZ1004W 5108 PAS20-36 PLZ1004W 5109 PAS20-54 PLZ1004W 5110 PAS40-27 PLZ1004W 5111 PWR800L PLZ164W
Q: Is it possible to configure the system with the equipment which are currently used?
If the used equipments are complied to the applicable model of the DC power supply and the electronic load, it is possible to configure the system with the PFX2511 to perform charge and discharge test.
* For details of the system configuration, please contact us.Applicable models
Power Supplies: PWR Series, PAS Series
Electronic loads: PLZ-4W Series
Q: How the adjustment or the calibration can be managed ?
The adjustment is not required when introducing the system. The periodic calibration of the PFX2511 provides securing the traceability of the entire system.
Lineup
| Model | Specification |
|---|---|
| PFX2511 | The system for charge and discharge testing can be configured with the selected Kikusui's electronic load and the DC power supply. The applicable maximum voltage : 60.0000 V, The applicable maximum current : 50.0000 A, The operating mode : Charge mode (CC-CV, CC ) / Discharge mode (CC, CP, CC Pulse, CP pulse), Equipped with an electric input/output terminal, load switch (route switch circuit), Supports temperature measurement, Included the application software "BPChecker2000 Basic edition (Up to 2CH)" > Manual... |
| PFX2121 | Control unit for PFX2000, PFX2511 > Manual... |
Options (Related products)









