KHA3000
Lineup
Data sheet
Note:To view the PDF file, please use Adobe Reader Ver.6 or later.
Operation Manuals
To download operation manuals (PDF), please use "Operation Manual Database".
Products Index > Harmonics and Flicker Testers > KHA3000
PRODUCTS
KHA3000
Harmonic/Flicker Analyzer for IEC61000-3-2/3/11/12, IEC61000-4/7/15
Outline
KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*. Furthermore, the KHA series is compliant with two measurement technique standards, the existing and the latest versions, so you can simply select to take measurements for the latest standard including interharmonics and for the conventional integral multiple harmonics without using any other device. In addition to the real-time display that can be used like an oscilloscope and FFT analyzer, the unit offers the real-time judgment of compliance with standards. Using this unit alone, you can judge test results and prepare result reports without the use of a PC. On top of that, you can easily set up a test system by combining KHA3000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).
*Support for measurement beyond 40A/phase is scheduled with a soon-to-be-released external current sensor (optional at extra cost) and an update of the firmware.
Features
- Supports harmonic and flicker compliance testing of single-phase and three-phase equipment
- Installed with the latest standards of both harmonic and flicker limits
- No need for a PC for compliance testing
- Real-time measurement that gives you a quick grasp of the EUT status
Lineup
| Model | Specification |
|---|---|
| KHA3000 | KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase. > Manual... |
Options (Related products)

Multi-outlet unit for KHA1000/3000. This unit allows you to connect various types of plugs used around the world.
Application software for KHA3000. This application lets you set test conditions and control the execution of the test. It also allows you to control the AC power supply (PCR-LA) used for the test. [Environmental requirements] Furthermore, you can print the harmonic spectrum and current and voltage waveforms on your reports. *Windows XP (x86, SP2 or later), Vista (x86/x64), 7(x86/x64), 8(x86/x64) *The PC must install Windows vista *Microsoft.NET Framework 2.0 *Memory space of 512 MB or more XGA or higher resolution *100 MB of free hard disk space *CD-ROM drive *VISA library (NIVISA4.1 or later, Agilent I/O Libraries Suite 14.1 or later, or KI-VISA 3.0.4 or later)

Single phase 500VA, AC1 to 300V, 1 to 999.9Hz, DC+/-1.4 to +/-424V, Liner-amp type, accommodate to power supply environment testing More...

Single phase 1kVA, AC1 to 300V, 1 to 999.9Hz, DC+/-1.4 to +/-424V, Liner-amp type, accommodate to power supply environment testing More...

Single phase 2kVA, AC1 to 300V, 1 to 999.9Hz, DC+/-1.4 to +/-424V, Liner-amp type, accommodate to power supply environment testing More...

Single phase 3kVA, AC1 to 300V, 1 to 999.9Hz, DC+/-1.4 to +/-424V, Liner-amp type, accommodate to power supply environment testing More...

Single phase 4kVA, AC1 to 300V, 1 to 999.9Hz, DC+/-1.4 to +/-424V, Liner-amp type, accommodate to power supply environment testing More...

Single phase 6kVA, AC1 to 300V, 1 to 999.9Hz, DC+/-1.4 to +/-424V, Liner-amp type, accommodate to power supply environment testing More...

Single phase 9kVA, AC1 to 300V, 1 to 999.9Hz, DC+/-1.4 to +/-424V, Liner-amp type, accommodate to power supply environment testing More...

Line impedance network unit to convert the output impedance of the PCR-L/LT series into the standardized value in IEC61000-3-2. (built to order)
Bracket (Inch size) for TOS6200, TOS9220/TOS9221, OH01-KHA More...