CURR:PROT

Sets the overcurrent protection (OCP) value.

Command

[SOURce:]CURRent:PROTection[:LEVel] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent:PROTection[:LEVel]? [{MINimum|MAXimum}]

Parameter

Value 10 % to 110 % of the rated current value (The default value is 110 % of the rated output current).
Unit A
A SCPI error (-222, "Data out of range") occurs if outside the range.

For the setting that is applied when *RST is sent, see this table.

Response

Returns the OCP value in NR3 format in response to CURR:PROT?.